Clear Login Information

If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted, or you have forgotten it, for
example), you can clear the login information with the following procedure:

1. Power off the switch and open the case.

2. Short the jumper J22 (labeled Restore Default Password) at the center front

of the switch’s main board.

3. Power on the switch.

When you power the switch on, the following message appears:

USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED.
PLEASE POWER OFF THE SWITCH, REMOVE THE JUMPER,
CLOSE THE CASE, THEN RESTART.

After you start back up, the OSD login function acts exactly the way it did the
first time the switch was run.