TERMINAL POSITION

mm

A - Directly below an open window or other opening

300

B - Below gutters, solid pipes or drain pipes

75

C - Below eaves

200

D - Below balconies or car-port roof

200

E - From vertical drain pipes and soil pipes

75

F - From internal or external corners

300

G - Above ground or below balcony level

300

H - From a surface facing a terminal

600

I - From a terminal facing a terminal

1200

J - From an opening in the car port

( e.g. door, window ) into dwelling

1200

K - Vertically from a terminal in the same wall

1500

L - Horizontally from a terminal in the same wall

300

11

B023

A

BC

D

E

F

G

J

K

HI

L

G

F

Fig. 2.5

Ø 60/100 mm

The boiler is designed to be connected to a coaxial flue discharge system.

A

Ø 80 mm

Ø 80 mm

In addition, it is also possible to use a twin-pipe (split) system by fitting a special
adaptor to the flue discharge collar and using one of the apertures for the air
vent intake located on the top part of the combustion chamber (A).

A

A

Fig. 2.7

Fig. 2.6

Advertising