2 technical information – Ariston EURO COMBI 47-116-10 User Manual

Page 4

Advertising
background image

CE Certification
Heat Input

max/min kW

25.6/11.0

Heat Output

max/min kW

23.1/9.2

Efficiency of Nominal Heat Input

%

90.2

Efficiency at 30% of Nominal Heat Input

%

87.8

Heat Loss to the Casing (³T=50°C)

%

1.2

Flue Heat Loss with Burner Operating

%

8.6

Flue Heat Loss with Burner Off

%

0.4

Maximum Discharge of Fumes (G20-G25) Kg/h

59

Residual Discharge Head

mbar

1.15

Consumption at Nominal Capacity (G20-G25) m

3

/h

2.72/3.32

Gas Consumption after 10 Minutes*

m

3

0.32/0.39

(15°C, 1013 mbar) (G30-G31)

Kg/h

2.02/2.00

Temp. of exhaust fumes at nominal

capacity (G20-G25)

°C

137

CO

2

Content

%

5.8

O

2

Content

%

9.2

CO Content

ppm

32

Minimum Ambient Temperature

°C

+5

Head Loss on Water Side (max) (³T=20°C) mbar

200

Residual Head of System

bar

0.25

Heating Temperature

max/min °C

82/42

Domestic Hot Water Temperature

max/min °C

56/36

D.H.W. Flow Rate ³T=35°C

l/min

9.5

D.H.W. Flow Rate ³T=35°C

gal/min

2.1

D.H.W. Minimum Flow Rate

l/min

2.6

Pressure of Domestic Hot Water

max/min bar

6/0.2

Expansion Vessel Capacity

l

7

Expansion Vessel Pre-load Pressure

bar

1

Maximum Water Content in System

l

145

Maximum Heating Pressure

bar

3

Nominal Pressure Natural Gas (G20-G25) mbar

20-25

LPG (G30-G31) mbar

30-37

Electrical Supply

V/Hz

230 / 50

Power Consumption

W

150

Protection Grade of Electrical System

IP

44

Internal Fuse Rating

FAST 2 AT

Weight

Kg.

47

G.C. Number

47-116-10

4

B023

1.2

Technical Information

chamber visually.

4 - Visual check of the combustion: clean burners if necessary.
5 - With reference to point 3, dismantle and clean the combustion chamber if

necessary.

6 - With reference to point 4, dismantle and clean the injectors if necessary.
7 - Visual check of the primary heat exchanger:

- check for overheating of the exchangers fins;
- clean the exhaust side of the exchanger and fan if necessary.

8 - Regulate the gas pressure, ignition pressure, partial flame, maximum

flame.

9 - Check proper operation of the heating safety system:

- maximum safety temperature;
- maximum safety pressure.

10 - Check the proper operation of the gas safety system:

- gas or flame safety device;
- gas valve safety device.

11 - Check that the electrical connections have been made in compliance with

the instructions shown in the installation instructions.

12 - Check the efficiency of the hot water supply (flow and temperature).
13 - Check general operation of the appliance.
14 - Check the exhaust system for the combustion products.

29.8/12.0
27.3/10.1

91.6
88.3

1.3
7.1
0.4

62

1.4

3.16/3.86
0.37/0.45
2.35/2.32

128

6.6

8.0

34
+5

200

0.25

82/42
56/36

11.2

2.5
2.6

6/0.2

7
1

145

3

20-25
30-37

230 / 50

190

44

FAST 2 AT

47

47-116-12

A/23 MFFI

A/27 MFFI

*Calculated at 70% maximum output

Advertising
This manual is related to the following products: