1c/p, 1 c/p 2, Pr ogrammer – Ariston EURO COMBI 47-116-10 User Manual

Page 24: Boiler, L1 n 2 e 3

Advertising
background image

24

B023

6.2

Wiring Diagram for
Connection to Ariston
Unvented Cylinder

V4043H

VALVE

BROWN

8

BLUE

2

GREY

9

ORANGE

10

GREEN/YELLOW

3

Hone

yw

ell ST 699B 1002

63

N

L

Link L-5-8

ST 6400/ST 6300 ST 6200

3

4

N

L

Dr

ayton T

empus

7

3

4

N

L

Horstmann 425, 525, 527

14

E

N

L

Link L-2-5

Landis & Gyr R

WB2

34

N

L

Glo

ww

or

m Master

mind

Landis & Gyr R

WB20

34

N

L

Microgyr

P

otter

ton Miniminder

3

4

N

L

P

otter

ton EP2000/3000 -

3

4

N

L

Link L-5 EP2001/3001

Randall 102/102 E

1

2

E

5

6

Link 3-6

Randall 4033

42

E

7

6

Link 1-6

Randall 701, 702

31

E

N

L

Link L-6-5

Sangamo M5

1

8

E

4

3

Link 1-6

Sangamo 410 F

or

m

1

18

E

4

3

Link 3-6

PR

OGRAMMER

64321

P

egler Sun

vic

25

E

N

L

SP 50/100 (Link L-3)

Switchmaster

14

N

L

Symphon

y,

Sonata

Switchmaster 400, 600

3

1

N

L

SWITCHMASTER 805, 900

31

N

L

Sun

vic ET 1451

74

E

1

2

Link 2-3-6

Sun

vic DHP 2201

6

3

E

1

2

To

w

erchron FP

61

0

2

1

Link 1-5/4-7-9

To

w

erchron MP

61

0

2

1

Link 1-4/6-11

To

w

erchron 2000

HW HTG

NL

O

N


ON

A

CL LS522, LS722

3

4

N

L

Randall 922, 972

36

E

N

L

Link L-2-5

Randall 3020 P

42

E

N

L

and 3060

PR

OGRAMMER

64321

A/27 MFFI - A/27 MFFI

E

N

L

Gen

us 23-27-30 MFFI

E

N

L

Gen

us 27 RFFI System

E

N

L

BOILER

9

10

3

2

240V

MAINS INPUT (3 AMP)

L

1

N

2

E

3

• 1

• 2

• 3

• 4

• 5

• 6

• 7

• 8

• 9

• 10

TYPICAL

JUNCTION BOX

T6360B

ROOM

THERMOSTAT

1

6

3

8

2

2

ZONE 2

V4043H

VALVE

BROWN

5

BLUE

2

GREY

9

ORANGE

10

GREEN/YELLOW

3

T6360B

ROOM

THERMOSTAT

1

4

3

5

2

2

ZONE1

ZONE 1

ZONE 1

ZONE 2

ZONE 2

1

BOILER ELECTRICAL SUPPLY CABLE

Remove internal time clock plug
from the the P.C.B. then connect
room stat terminal block on the
reverse of the boiler control panel

(see section 2.10)

to 9 + 10 on

the junction box.

If a room thermostat is not requied on Zone 1, insert a link

between 4 + 5 on the junction box.

If a room thermostat is not requied on Zone 2, insert a link

between 6 + 8 on the junction box.

Hone

yw

ell ST 699B 1002

63

N

L

Link L-5-8

ST 6400/ST 6300 ST 6200

3

4

N

L

Dr

ayton T

empus

7

3

4

N

L

Horstmann 425, 525, 527

14

E

N

L

Link L-2-5

Landis & Gyr R

WB2

34

N

L

Glo

ww

or

m Master

mind

Landis & Gyr R

WB20

34

N

L

Microgyr

P

otter

ton Miniminder

3

4

N

L

P

otter

ton EP2000/3000 -

3

4

N

L

Link L-5 EP2001/3001

Randall 102/102 E

1

2

E

5

6

Link 3-6

Randall 4033

42

E

7

6

Link 1-6

Randall 701, 702

31

E

N

L

Link L-6-5

Sangamo M5

1

8

E

4

3

Link 1-6

Sangamo 410 F

or

m

1

18

E

4

3

Link 3-6

PR

OGRAMMER

64321

P

egler Sun

vic

25

E

N

L

SP 50/100 (Link L-3)

Switchmaster

14

N

L

Symphon

y,

Sonata

Switchmaster 400, 600

3

1

N

L

SWITCHMASTER 805, 900

31

N

L

Sun

vic ET 1451

74

E

1

2

Link 2-3-6

Sun

vic DHP 2201

6

3

E

1

2

To

w

erchron FP

61

0

2

1

Link 1-5/4-7-9

To

w

erchron MP

61

0

2

1

Link 1-4/6-11

To

w

erchron 2000

HW HTG

NL

O

N


ON

A

CL LS522, LS722

3

4

N

L

Randall 922, 972

36

E

N

L

Link L-2-5

Randall 3020 P

42

E

N

L

and 3060

PR

OGRAMMER

64321

A/27 MFFI - A/27 MFFI

E

N

L

Gen

us 23-27-30 MFFI

E

N

L

Gen

us 27 RFFI System

E

N

L

BOILER

9

10

3

2

• 1

• 2

• 3

• 4

• 5

• 6

• 7

• 8

• 9

• 10

TYPICAL

JUNCTION BOX

1

BOILER ELECTRICAL SUPPLY CABLE

Remove internal time clock plug
from the the P.C.B. then connect
room stat terminal block on the
reverse of the boiler control panel

(see section 2.10)

to 9 + 10 on

the junction box.

T6360B

ROOM

THERMOSTAT

1

4

3

5

2

2

V4043H

HEATING VALVE

BROWN

5

BLUE

2

GREY

9

ORANGE

10

GREEN/YELLOW

3

V4043H

HOT WATER VALVE

BROWN

8

BLUE

2

GREY

9

ORANGE

10

GREEN/YELLOW

3

1

C/P

Cylinder

thermostat

Thermal

cut-out

1

8

6

Not

used

P

2

1 C/P

2

240V

MAINS INPUT (3 AMP)

L

1

N

2

E

3

Based on Hone

yw

ell controls

Advertising
This manual is related to the following products: