10 room thermostat connection – Ariston EURO COMBI 47-116-10 User Manual

Page 14

Advertising
background image

14

B023

5 Remove the grommet “D” shown in photo 5, make a hole in it and pass

the room thermostat wire through.

6 Remove the link located on the terminal and connect the wire.
7 Replace the grommet and the terminal to their original positions, close the

cover on the grommet compartment and fasten the wire-clamp “C” in place.

8 If a remote time clock is to be fitted, disconnect the integral time clock plug

from the P.C.B.

9 Using a volt-free switching time clock, connect the switching wires from the

time clock following points 1-7 above.

10 If using a time clock and room thermostat, these must be connected in

series as per points 1-9 above.

Note:

Only a two-wire type room thermostat can be used.

2.10 Room Thermostat

Connection

3

4

5

6

7

D

C

B

C

1

A

2

In order to perform this procedure, remove boiler cover as indicated in section
3.2. Then proceed as follows:
1 Remove the screws “A” located on the bottom part of the boiler;
2 Widen the sides so that the control panel can be rotated.
3 Open the cover “B” on the left hand side of the compartment.
4 Insert the wire for the connection of the room thermostat into the wire

holder “C”, as indicated in photo 3.