Antenna Subsystem Return Loss Test

Antenna Subsystem return loss measurement verifies the performance of the transmit and
receive antennas. This measurement can be used to analyze the performance of the antenna
before installation. The antenna can be tested for the entire frequency band, or tested to a
specific frequency range. Transmit and receive frequency measurements are conducted sep-
arately. The following steps explain how to measure the antenna loss in return loss mode.

Required Equipment

q

Site Master Model S113C, S114C, S331C, or S332C

q

Precision Open/Short, Anritsu 22N50 or
Precision Open/Short/Load, Anritsu OSLN50LF

q

Precision Load, Anritsu SM/PL

q

Test Port Extension Cable, Anritsu 15NNF50-1.5C

q

Optional 510-90 Adapter, DC to 7.5 GHz, 50 ohm, 7/16(F)-N(M)

q

Anritsu InstaCal Module, ICN50

Device Under Test

q

Antenna Sub Assembly

Procedure

Step 1. Press the

MODE

key.

Step 2. Select

FREQ-RETURN LOSS using the Up/Down arrow key and press

ENTER

.

Step 3. Connect the Test Port Extension cable to the RF port and calibrate the Site Mas-

ter as described on page 3-2.

Step 4. Press

SAVE SETUP

and save the calibration set up (page 3-7).

Step 5. Connect the Device Under Test to the Site Master phase stable Test Port Exten-

sion cable.

Step 6. Press the

MARKER

key.

Step 7. Set markers M1 and M2 to the desired frequency.

Step 8. Record the lowest return loss over the specified frequency.

Step 9. Press

SAVE DISPLAY

(page 3-8) name the trace, and press

ENTER

.

4-10

Chapter 4 Cable & Antenna Measurements