Pre ven tive main te nance 1-6, Cal i bra tion 1-6 – Anritsu S331C User Manual

Page 12

Advertising
background image

1 - 5

Chapter 1

General Information

Spectrum Analyzer:
Frequency Range

S114C
S332C

100 kHz to 1.6 GHz
100 kHz to 3.0 GHz

Frequency Reference

Aging
Accuracy

±1 ppm/yr
±2 ppm

Frequency Span

S114C
S332C

0 Hz (zero span) 100 kHz to 1.6 GHz
0 Hz (zero span) 100 kHz to 3.0 GHz

Sweep Time

³

650 ms (full span)

500 ms (zero span)

Resolution Bandwidth

Accuracy

10 kHz, 30 kHz, 100 kHz, 1 MHz
± 20% typical

Video Bandwidth

100 Hz to 300 kHz in 1-3 sequence

SSB Phase Noise (1 GHz) @ 30 kHz offset

£

–75 dBc/Hz

Spurious Responses, Input Related

£

–45 dBc

Spurious Residual Responses

£

–95 dBm

Note: 10 kHz resolution bandwidth, input terminated, no attenuation
Amplitude
Measurement Range

–97 dBm to +20 dBm typical

Dynamic Range

³

65 dB typical

Maximum Safe Input Level

+20 dBm, maximum measurable safe input
+27 dBm, maximum input (damage)
+27 dBm, peak pulse power
+50 Vdc

Displayed Average Noise Level:

£

–80 dBm (100 kHz to 300 kHz) typical

£

–97 dBm (>300 kHz) typical

Display Range, Log Scale

2 to 15 dB/div. in 1 dB steps; 10 divisions displayed.

Frequency Response
RF Input VSWR

2.0:1

Resolution (Ref. Level)

1.0 dB

Total Level Accuracy

±2 dB

³

300 kHz typical

±

3 dB <300 kHz typical

General
Internal Memory:

Trace Memory

Instrument configuration
RS-232

200 maximum
10 setup locations
9 pin D-sub, three wire serial

Electromagnetic Compatibility

Complies with European community requirements
for CE marking

Power Supply:

External DC Input

+12.5 to +15 Vdc, 1100 mA max.

Temperature:

Storage
Operating

–20° C to 75° C

0° C to 50° C

Weight:

2.15 kg (4.76 pounds)

Dimensions:

25.4 x 17.8 x 6.1 cm
(10 x 7 x 2.4 inches)

* ±2 ppm/

D°C from 25°C

** Fault location is accomplished by inverse Fourier Transformation of data taken with the Site Master. Resolution and
maximum range depend on the number of frequency data points, frequency sweep range and relative propagation velocity
of the cable being tested.
*** Immunity measurement is made in CW mode with incoming interfering signal exactly at the same frequency (worst
case situation). Typical immunity is better when swept frequency is used.

Table 1-2.

Performance Specifications (2 of 2)