Auto scale 3-7, Am pli tude scale 3-7, Save and re call a setup 3-7 – Anritsu S331C User Manual

Page 47: Saving a setup 3-7, Instacal module calibration procedure, Calibration with the test port extension cable, Chapter 3 getting started, Start cal, Enter, Cal on

Advertising
background image

InstaCal Module Calibration Procedure

The InstaCal module automatically calibrates the Site Master using the OSL method.

NOTE: The InstaCal module is not a discrete calibration component and it can
not be used at the top of the tower to perform line sweep measurements.

Check that the “CAL OFF” message is displayed in the upper left corner of the display.
This indicates that the Site Master has not been calibrated. The following procedure details
how to perform the calibration using the InstaCal module.

Step 1. Select the appropriate frequency range, as described in the procedure above.

Step 2. Press the

START CAL

key. The message “CONNECT OPEN or InstaCal TO RF

Out PORT” will appear in the display.

Step 3. Connect the InstaCal module to the RF Out port.

Step 4. Press the

ENTER

key. The Site Master senses the InstaCal module and automati-

cally calibrates the unit using the OSL procedure. The calibration should take
about 45 seconds.

Step 5. Verify that the calibration has been properly performed by checking that the

CAL ON!

message is displayed in the upper left corner of the display.

Calibration with the Test Port Extension Cable

If a Test Port Extension Cable is to be used, the Site Master must be calibrated with the
Test Port Extension Cable in place. Follow the same calibration procedures as above with
the OSL components or the InstaCal module in place at the end of the test port extension
cable.

3-6

Chapter 3 Getting Started

In

sta

Ca

l

Mo
de

lI

CN

50

10
M

H

z-
4.0

G

H

z

InstaCal

MODULE

HOLD

RUN

START
CAL

AUTO
SCALE

SAVE
SETUP

RECALL
SETUP

LIMIT

MARKER

SAVE
DISPLAY

RECALL
DISPLAY

PRINT

MODE

FREQ/DIST

AMPLITUDE

SWEEP

SYS

ENTER

CLEAR

ESCAPE

ON

OFF

/

1

2

4

5

6

7

8

9

0

3

+

-

.

Site Master S332C

Figure 3-3.

InstaCal Module Calibration