Figure 4-5 shows an example of a typical DTF return loss trace.

In the above example:

q

Marker M1 marks the first connector, the end of the Site Master phase stable Test
Port Extension cable.

q

Marker M2 marks the first jumper cable.

q

Marker M3 marks the end of the main feeder cable.

q

Marker M4 is the load at the end of the entire transmission line.

Procedure - DTF-SWR Mode

The following steps explain how to measure DTF in SWR mode.

Step 1. Press the

MODE

key.

Step 2. Select the

DTF-SWR

using the Up/Down arrow key and press

ENTER

.

Step 3. Follow the same procedure as DTF-Return Loss Mode, above.

4-9

Chapter 4 Cable & Antenna Measurements

Figure 4-5.

Typical DTF Return Loss Trace