En tering an tenna fac tors 7-7, Plot capture, Plot properties – Anritsu S331C User Manual

Page 81

Advertising
background image

Plot Capture

To open the plot capture menus, select the capture icon on the button bar, or select the

Cap-

ture

drop down menu from the menu bar.

Select

Capture to Screen

to download traces to the PC.

Highlight a folder, or highlight individual traces within a folder, to be downloaded to the
PC. The traces will appear on the PC display as they are downloaded.

Plot Properties

After downloading, certain plot properties and information can be modified. Select the Plot
Properties or Plot Information icon.

Plot Properties that can be changed include:

Graph Titles
Display Mode
Scale/Limit
Markers
Misc.

Graph Titles

After downloading the plot, the

Main Title can be changed to reflect the site name or other

descriptive information. The

Sub Title field can be used to describe the specifics of the

measurement and configuration.

Display Mode

Display Mode allows changing the display type without having to retest. Plots can be
changed from

Return Loss

to

VSWR

with single click of mouse button.

Scale/Limit

The scale of the displayed plot can be modified to help analyze whether the plot meets
pass/fail criteria. The Scale/Limit sub menu activates options to manually enter the scale
limits, or to use the Auto Scale mode.

Manual

adjustment sets the upper and lower limits of the display under the

Scale/Limit Submenu.

Auto Scale

automatically adjusts the scale for maximum and minimum mea-

surement readings.

Limit Line Off

turns off all limit lines.

Single Limit Line

can be activated to help identify faults. Typical antenna speci-

fications require better than –15 dB return loss.

Multi-Segment Limit Lines

can be activated to set different limits within the

same measurement display for specification requirements.

7-4

Chapter 7 Software Tools Program