Appendix A
Reference Data

Coaxial Cable Technical Data

Table A-1 provides a standard listing of common coaxial cables along with their Relative
Propagation Velocity and Nominal Attenuation values in dB/m @1000, 2000, and
2500 MHz. (N/A indicates that the specification is not applicable to the listed cable.)

A-1

Manufacturer

Cable Type

Relative

Propagation

Velocity (Vf)

Nominal

Attenuation

dB/m @

1000 MHz

Nominal

Attenuation

dB/m @

2000 MHz

Nominal

Attenuation

dB/m @

2500 MHz

Andrew

FSJ1-50A

0.84

0.197

0.285

0.323

Andrew

FSJ2-50

0.83

0.134

0.196

0.224

Andrew

FSJ4-50B

0.81

0.119

0.176

0.202

Andrew

LDF4-50A

0.88

0.077

0.113

0.133

Andrew

LDF5-50A

0.89

0.043

0.064

0.077

Andrew

LDF6-50

0.89

0.032

0.048

0.056

Andrew

LDF7-50A

0.88

0.027

0.041

0.047

Andrew

LDF12-50

0.88

0.022

0.035

N/A

Andrew

HJ4-50

0.914

0.087

0.126

0.15

Andrew

HJ4.5-50

0.92

0.054

0.079

0.084

Andrew

HJ5-50

0.916

0.042

0.063

0.07

Andrew

HJ7-50A

0.921

0.023

0.034

0.04

Andrew

HJ12-50

0.931

0.019

0.029

N/A

Belden

RG8, 8A

0.659

0.262

N/A

N/A

Belden

RG9, 9A

0.659

0.289

N/A

N/A

Belden

RG17, 17A

0.659

0.18

N/A

N/A

Belden

RG55, 55A, 55B

0.659

0.541

N/A

N/A

Belden

RG58, 58B

0.659

0.558

N/A

N/A

Belden

RG58A, 58C

0.659

0.787

N/A

N/A

Belden

RG142

0.659

0.443

N/A

N/A

Belden

RG174

0.659

0.984

N/A

N/A

Belden

RG178B

0.659

1.509

N/A

N/A

Belden

RG188

0.659

1.017

N/A

N/A

Belden

RG213

0.659

0.292

N/A

N/A

Belden

RG214

0.659

0.292

N/A

N/A

Belden

RG223

0.659

0.535

N/A

N/A

Table A-1.

Coaxial Cable Technical Data (1 of 3)