Wiring the axb-irs4, Wiring guidelines, Preparing/connecting captive wires – AMX Interface Port AXB-IRS4 User Manual

Page 10: Wiring guidelines at 125 ma

Advertising
background image

Configuration and Installation

6

AXB-IRS4 IR/Serial Interface (4 Ports)

Wiring the AXB-IRS4

The serial, IR, AXlink, and power supply connectors are located on the rear panel of the AXB-IRS4

as shown in FIG. 5. The AXlink connector can also be used for RS-232 communications.

Wiring Guidelines

The AXB-IRS4 requires 12 VDC power to operate properly. The power can be supplied by the

AMX system's AXlink cable or with an optional 12 VDC power supply. The maximum wiring

distance between the control system and AXB-IRS4 is determined by power consumption, supplied

voltage, and the wire gauge used for the cable. The following table lists wire sizes and the

maximum lengths allowable between the AXB-IRS4 and control system. The maximum wiring

lengths for using AXlink power are based on a minimum of 13.5 volts available at the control

system's power supply.

If the AXB-IRS4 is installed farther away from the control system than recommended in the Wiring

Guidelines table, connect a 12 VDC power supply to the 2-pin 12 VDC PWR connector on the rear

panel.

Preparing/connecting captive wires

1.

Strip 0.25 inch of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector according to the wiring

diagrams and connector types described in this section. Do not tighten the screws excessively;

doing so may strip the threads and damage the connector.

FIG. 5 AXB-IRS4 rear panel connectors

GND

SER

SER

IR

GN

D

GND

GN

D

IR

IR

GN

D

SER

IR

SER

GND

GN

D

AXM / RX

AXP /

TX

GND

GND

PWR

12VDC

4

3

2

1

AXlink / RS-232

PWR

Do not connect power to the AXB-IRS4 until the wiring is complete. If you are using
power from AXlink, disconnect the wiring from the Card-Frame before wiring the
AXB-IRS4. If you are using an optional 12 VDC power supply, apply power to the
AXB-IRS4 only when the installation is complete.

Wiring Guidelines at 125 mA

Wire Size

Maximum Wiring Length

18 AWG

938.97 feet (286.19 m)

20 AWG

594.06 feet (181.07 m)

22 AWG

370.37 feet (112.89 m)

24 AWG

233.46 feet (71.16 m)

Advertising