Remote control connections, Channel switching via rs232 control – Adder Technology SmartView User Manual

Page 10

Advertising
background image





























Remote control connections

The remote control unit can be used to provide manual switching between
systems.

To connect the remote control

1 Locate the remote control unit and the remote control cable. Attach the

smaller of the two cable connectors to the socket at the rear of the remote
control.

1A

1B

1C

OPT

ION

S / FLA

SH

2 At the other end of the cable, attach the larger connector to the

OPTIONS/

FLASH

socket on the right side of the Adder unit rear panel.

Channel switching via RS232 control

The Adder SmartView Multiscreen Serial can be controlled by a remote RS232
serial device. To do this, the serial device must be connected to the

OPTIONS/

FLASH

port on the rear panel of the unit using an appropriate link cable.

1A

1B

1C

OPT

ION

S / FLA

SH

The serial device must use the following speed/protocol settings:
1200 baud, 8 bits, no parity and 1 stop bit.
No handshaking is used by the SmartView Multiscreen Serial.
To perform the switching operation, simply send the character for the required
channel, for example ASCII ‘1’ (hex code 31) will select channel 1, ASCII ‘2’ (hex
code 32) will select channel 2 and so on. The SmartView Multiscreen Serial will
echo the ASCII character back to the sending device when the channel has been
changed.

Pin assignments for the

OPTIONS/

FLASH

port on the rear panel are

as follows:
Pin 9 = GND
Pin 10 = TXD
Pin 11 = RXD
Other pins to be left unconnected.