Use this air conditioner under the following temperature range

Single Split Outdoor Unit (CU-E7MKE, CU-E9MKE, CU-E12MKE, CU-E15MKE, CU-E18MKE, CU-E21MKE)

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

Min.

16

11

5

4

HEATING

Max.

30

-

24

18

Min.

16

-

-5

-6

NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -5°C.

When the outdoor temperature is below -5°C and you use this model out of above conditions, the outdoor unit might be

frozen up and stop operation for protection control.

Multi Split Outdoor Unit (CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)

Temperature (°C)

Indoor

Outdoor

Outdoor

CU-2E15LBE, CU-2E18LBE,

CU-4E27CBPG

CU-3E18LBE, CU-4E23LBE

*DBT

*WBT

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

46

26

Min.

16

11

16

11

-10

-

HEATING

Max.

30

-

24

18

24

18

Min.

16

-

-10

-11

-15

-16

* DBT: Dry bulb temperature
* WBT: Wet bulb temperature

Single Split Outdoor Unit (CU-E7MKE-3, CU-E9MKE-3, CU-E12MKE-3)

Temperature (°C)

Indoor

Outdoor

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

Min.

16

11

5

4

HEATING

Max.

30

-

24

18

Min.

16

-

-15

-16

NOTICE: • This model is not suitable for 24 hours non-stopping operation in heating mode below -15°C.

When the outdoor temperature is below -15°C and you use this model out of above conditions, the outdoor unit might be

frozen up and stop operation for protection control at -18°C.