Cables used with a-net devices, Cat-5e cable lengths, System bridge – Aviom AV-P2 User Manual

Page 11

Advertising
background image





Pro16 Input Module

Pro16 Output Modules,
A-Net Distributors, or
Personal Mixers

Up to 500 feet
of Cat-5e cable
can be used to
connect
each system
component

Infinite
number
of A-Net
components

This diagram shows a Pro16 input module connected to compatible

Pro16 devices. Each cable shown can be up to 500 feet in length.

System Bridge

In systems using the optional AN-16SBR System Bridge, the cable length
specification applies to the total cable length between the A-Net devices
being connected and the AN-16SBR components.

Pro16 Input

Pro16 Output

Total A-Net cable length can be 500 feet (150 meters)

System

Bridge

A-Net Out

A-Net In

System

Bridge

The maximum cable length calculation includes any cables used to

connect Pro16 devices to a System Bridge.

Cables Used With A-Net Devices

All Cat-5e connections between A-Net devices should use Unshielded
Twisted Pair (UTP) cable. The cable can be of the stranded or solid type;
solid wire performs better over long distances, while stranded wire is
more flexible and easier to manipulate and therefore easier to work
with in a performance situation.

Cables designated as Cat-5e in this User Guide can be interchanged with
any Cat-6 (or better) cable. Cables will be referred to simply as “Cat-5e.”

Connectors on Cat-5e cables can be of the standard RJ45 variety or
locking Neutrik® EtherCon® type.

P

N

ote

: When purchasing Category 5e cables, be sure to buy only

standard Cat-5e cables, not those sold as crossover cables.
A crossover cable is used for file transfer between two
computers. A crossover cable is not compatible with your
Aviom equipment.

Cat-5e Cable Lengths

Category 5e cables used with your Aviom products can be up to 500
feet (approximately 150 meters) in length. The maximum cable length
specification applies to the cable connected between the Pro16 input
module and the first A-Net device (AV-P2, AN-16/o Output Module,
Personal Mixer, etc.), as well as for cable runs between each additional
A-Net compatible device in your system.

Your cable length performance will be affected by a number of factors
,including the quality of the cables used and the number of devices
such as cable couplers or wall panel interconnections in use. Use Cat-5e
or higher cables for best performance wherever possible.

For cable runs in excess of 500 feet between A-Net devices, fiber optic
media converters can be used.