Bit

Hexagonal bit chuck

9.5 mm (3/8") - 13 mm (33/64") 6.35 mm (1/4")

Clutch Handle

(Clutch Torque Setting)

Adjust the torque to one of the 1 pos-

sible settings to the job. There is an

interval of about 0.13 N·m (1.3 k f-cm

or 1.1 in-lbs) between steps.

CAUTION:

Test the setting before actual opera-

tion.

Set the scale at this mark.

Reference for Adjusting Torque

Setting

Torque

Use

1

Approx: 0.9 N·m

(3.0 kgf-cm or .6 in-lbs)

For driving

screws

5

Approx: 0.8 N·m

(8.4 kgf-cm or 7.3 in-lbs)

9

Approx: 1.35 N·m

(13.8 kgf-cm or 1.0 in-lbs)

13

Approx: 1.88 N·m

(19. kgf-cm or 16.6 in-lbs)

17

Approx: .41 N·m

(4.6 kgf-cm or 1.3 in-lbs)

1

Approx: .94 N·m

(30.0 kgf-cm or 6.0 in-lbs)

Approx: 4.4 N·m

(45.0 kgf-cm or 39.0 in-lbs)

For power-

ful driving

screws and

drilling

● When using at high speeds, set the

clutch at 10 or below. (Operation

stops at the maximum torque of 1.5

N·m (15 kgf-cm) when the scale is

higher.)

● The auto shut-off function may

become inoperable at high clutch

settings when battery power drops.

Recharge the battery in that case.

NOTE:

The chart is only a reference. The

torque settings may differ by materi-

als, types of screws, etc. Please test

it at your own conditions before use.

Control Panel

Manufacturer settings upon shipment

Count system: Count down system

Count setting value: 99

Buzzer sound pitch: b1 (Low sound)

Double tightening counting preven-

tion count time: 0 (OFF)

Hold switch: Released

Please set the settings according to

conditions of use.

Screw count function

● Counts the number of auto stops.

(Counts the number of screws driven)

● The count method can be selected

from “UP” or “DOWN”.

● When the set number of screws to be

driven is reached, a buzzer sounds

and the count value is reset.

● The buzzer sound can be selected

from 3 types of sound.

● Double tightening counting prevention

function

Work (double tightening and screw

driving confirmation, etc.) that began

within the set time is not counted after

the driven screws are counted.

Count display lamp

Count system display