AXIS 221 - Unit Connectors

I/O terminal connector pinout table

I/O terminal connector schematic diagram
Example schematic diagram of the AXIS 221 terminal connector - showing possible

applications.

o

o

Control

Device

o

o

o

o

A

B

3

4

5

6

7
8

External Device

Active

_

+

o

o

1

2

RS-485

Mains Power

24V DC

Appliance

Optional

Relay

Switch

o

o

o

o o

o

o

o

o

9

10

+

-

Switch, etc.

Pin

Function Description

1

Output A

On the external device output terminals (A and B), there is no distinction between
positive and negative (+ and -). The terminals use a photocoupler and are electri-
cally isolated from the other internal circuitry.

The maximum load should not exceed 100mA and the maximum voltage should be
not more than 50V DC. Note: Connecting AC to the output will damage the unit.

2

Output B

3

Digital Input 1
Photocoupler Anode (+)

Photocoupled Input 1. Electrically isolated from the chassis and connectors, this
input can be supplied from an external DC voltage or the DC Power Input/Output on
pins 9 (DC+) and 10 (GND).

4

Digital Input 1
Photocoupler Cathode (-)

5

Digital Input 2
Photocoupler Anode (+)

Photocoupled Input 2. As above.

6

Digital Input 2
Photocoupler Cathode (-)

7

RS-485-A (non-inverting)

A half-duplex RS-485 interface for controlling auxiliary equipment.

8

RS-485-B (inverting)

9

DC + Power Output

This can drive the photocoupler inputs or other equipment. The output voltage level
is 3.0 V. A maximum current of 100mA can be sourced from the DC output.

10

GND

Ground.