COOK LSUG User Manual

Pr / tr / lsug, Installation, operation, and maintenance manual, Receiving and inspection

Advertising
background image

1

Relief or Intake Ventilators

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

This publication contains the installation instructions for

standard units of the PR / TR / LSUG - Relief or Intake
Ventilator. Carefully read this publication prior to any
installation procedure.

Carefully read this publication and any
supplemental documents prior to any
installation or maintenance procedure.

Loren Cook Company’s Gravity Catalog provides

additional information describing the equipment, unit
performance, available accessories, and specification data.

For additional safety information, refer to AMCA

publication 410-96, Safety Practices for Users and
Installers of Industrial and Commercial Fans
.

All of the publications listed above can be obtained from

Loren Cook Company by phoning 417/869-6474, extension
166; by FAX at 417/832-9431; or by e-mail at
[email protected].

For information on special equipment, contact Loren

Cook Company Customer Service Department at
(417)869-6474.

Receiving and Inspection

Immediately upon receipt of a PR / TR / LSUG unit,

carefully inspect it for damage and shortage.

• Check dampers (if supplied) for free operation of all

moving parts.

• Record on the Delivery Receipt any visible sign of

damage.

Handling

Lift the PR / TR / LSUG units by the base or shipping
carton. The LSUG may be lifted by the lifting lug, as
indicated on the parts list. NOTICE! Never lift by the top
caps or windband.

Storage

If the unit is stored for any length of time prior to

installation, store it in its original shipping crate and protect
it from dust, debris and the weather.

Installation

Damper Installation

If your unit is supplied with dampers, follow the directions

below. If your unit does not include dampers, proceed to unit
installation.

When dampers are supplied:
a) Place dampers inside the curb, ensuring that the

damper will open freely in the correct direction of
airflow.

b) Secure to curb at damper tray.
c) When motorized damper kits are supplied, follow

installation instructions provided with kit. Drill hole in
curb shelf for wiring (if needed).

PR / TR / LSUG

Unit Installation

Secure ventilator to curb using lag screws, anchor bolts, or

suitable fasteners.

(Parts list on back)

The attachment of roof mounted fans to the roof curb
as well as the attachment of roof curbs to the building
structure must exceed the structural requirements
based on the environmental loading derived from the
applicable building code for the site. The local code
official may require variations from the recognized
code based on local data. The licensed engineer of
record will be responsible for prescribing the correct
attachment based on construction materials, code
requirements and environmental effects specific to
the installation.

Failure to follow these instructions could result in
death or serious injury.

PR

TR

LSUG

Advertising
This manual is related to the following products:

TR, PR