Choose a location near a grounded electrical outlet. For the most efficient operation, the refrigerator
should be located where the temperatures will not drop below 10°F (-12°C) or exceed 110°F (43°C).
The Freeze Control Feature in the refrigerator is designed to automatically maintain the selected
interior refrigerator temperature within these temperature limits.

Allow adequate space around the unit for good air circulation. A minimum of 3 inches (75 mm)
space on all sides of the refrigerator is required for adequate air circulation.
Note: The exterior walls of the refrigerator may become quite warm as the compressor works to
transfer heat from the interior. Temperatures as much as 30°F (-1°C) warmer than room
temperature can be expected. It is particular in hotter climates to allow adequate space for air
circulation around the refrigerator.

ELECTRICAL


Check the proposed outlet to be used to insure that the voltage, phase, and current carrying
capacity of the circuit from the electrical panel correspond to the requirements of the cabinet.
NEVER use an extension cord or adapter plug to wire any unit. Refer to the serial tag for all
pertinent electrical information.

The refrigerator must be plugged into its own 115 volt, 60 Hz, single phase outlet. The power cord
of the refrigerator is equipped with a three-prong grounding plug for protection against shock
hazards. It must be plugged into a properly grounded three-prong receptacle. The receptacles must
be installed in accordance with local codes and ordinances.

If voltage varies by more than 10%, refrigerator performance may be affected. Operating the
refrigerator with insufficient power can damage the compressor.

To prevent the refrigerator from being accidentally turned off, do not plug the unit into an outlet
controlled by a wall switch or pull cord. Do not pinch, knot or bend the cord in any manner.

Observe all Warning Labels. Disconnect power supply to eliminate injury from electrical
shock or moving parts when servicing equipment.



OPERATION


Cool Down Period
For safe storage of product, allow a minimum of four hours for the refrigerator to cool down
completely. The refrigerator will run continuously for the first several hours.

Temperature Control
The temperature control is located inside the refrigerator. The temperature is factory preset to
provide satisfactory product storage temperatures. The temperature control is adjustable to provide
a range of temperatures for any desired application. If a colder temperature is required, turn the
temperature control knob toward COLDEST and allow several hours for temperatures to stabilize
between adjustments. The Automatic Freeze Control feature will maintain proper interior refrigerator
temperature even when the ambient exterior temperature drops to 10°F (-12°C).


Door Removal
If the door must be removed to fit through a narrow passageway:

1. Lay the refrigerator on its back on a cover protect its exterior surface.
2. Remove the base panel by unscrewing two screws from the front of the panel.
3. At the top of the cabinet, lift up the plastic hinge cover and fold back (see the illustration