TROUBLESHOOTING

13

L20-259, rev. 7 (09/13)


4.4. TROUBLESHOOTING

CHART













4.5. ELECTRICAL

SCHEMATIC



Problem

Probable Cause

Corrective Action

No power to appliance

Check main building power supply

Circuit breaker tripped

Reset power supply Circuit Breaker

I/O swich in the O (off) position

Press the power switch to the start Position
and release

Power cord disconnected

Check power cord connection

High temperature limit tripped

Allow the appliance to cool to room temperature
and the high limit switch will auto-reset.

Low water level

Fill appliance with water level fill line(s)

Circuit breaker tripped

Reset power supply Circuit Breaker

High temperature limit tripped

Allow the appliance to cool to room temperature
and the high limit switch will auto-reset.

Low water level

Fill appliance with water level fill line(s)

Control does not

activate

Appliance stops

heating