Pitco Frialator Solstice I12 Cooking Computer Single Vat User Manual

Page 4

Advertising
background image

Solstice I12 Cooking Computer Operations
Single Vat (60126801) and Dual Vat (60126802)

L20-282 Rev 0 (2/07)

4

4

running, or, [CKn mm:ss] for any cooks still running.

To view the set temperature, press the thermometer key twice. The display will
show [SET nnnF] or [SET nnnC], where nnn is the current set temperature.
After a few moments, the display will return to [READY], [MELT ], or
[HEATING] , or, [CKn mm:ss] for a cook still running.

1.6

To View Current Settings for cook, shake, and hold times:

To view the current settings for any product key, press the clock key, followed
by the desired product key.

The display will show [CKn mm:ss], followed by [SHn mm:ss], then [HDn mm:ss]. Where “n” is
the key number, and “mm:ss” are the current settings for time. After a few moments, the display
will return to [READY], [MELT ], or [HEATING] , or, [CKn mm:ss] for a cook still running.

Typical displays using key 4 as an example:

Key 4 set for 3 minutes and 28 seconds cook time.

Key 4 Shake Time is set for 2 minutes and :00 seconds before
the end of the Cook.

Key 4 Hold Time in set for 10:00 minutes.

In a few moments, the display will return to [READY]

1.7

To perform a Boil Out operation:

Normal maintenance of a fryer requires regular tank cleaning. This process involves draining the
vat of oil and filling with water. Cleaning solution is added, and the control is set to the boil out
mode by one of the following methods:

1.7.1 Automatic Boil Entry (Water Detection):
After filling an empty vat with water, turn the appliance On. Heat will be applied to the vat
warming the water. This control will detect the presence of water by temperatures not
rising above the boiling point of water; 212°F (100°C). After a time at this temperature,
displays will show:

Heat will be disabled until the operator responds to this prompt. Pressing the [0] key is a
YES response to the boil prompt. If pressed, display will show:

Heat will maintain vat temperature at 185°F (85°C) for cleaning as long as the control
remains on. To exit boil mode control must be turned off.

Warning: Pressing any other key at the [PRESS 0 ] [TO BOIL ] prompt is regarded by the
control as a NO response. With this response, the control will apply heat to the vat as if
oil were present in the vat. With water in the vat, a rolling boil will result. This will cause
undesirable foam over conditions, and steam burn hazards to operators performing
cleaning operations.