5

6

7

8

3.5

Melt Cycle Type:

This adjustment allows selection of the melt cycle type, or, disabling the melt cycle requirement
when starting the appliance from a cold start.

With display showing [PROGRAM], press the product key [0].

Display will show [SELECT] [OPTIONS].

Press product key 5, display shows [LIQUID], the default setting.

Use the product key [0] to scroll through choices (liquid, solid, no melt).

Press [P] key to save choice. Display will again return to [PROGRAM].

3.6

Recovery Test Value:

This controller maintains a record of heat up times for the appliance. A poorly running appliance
will have increased recovery times stored in this display. There is no selection done here, just the
display of recovery time values.

With display showing [PROGRAM], press the product key [0].

Display shows [SELECT] [OPTIONS].

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery value,
and yyy is the last warm up recovery value.

After recording these values, press the [P] key. Display returns to [PROGRAM].

3.7

Control or Timer: (Left side of Dual or Single Vat)

With display showing [PROGRAM], press the product key [0].

Display shows [SELECT] [OPTIONS].

Press product key 7; display will show [CONTROL].

Use the product key [0] to scroll through choices (Control, Timer).

Press [P] key to save choice. Display shows [PROGRAM].

Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions
active. Do not make this selection on Solstice fryer models.

3.8

Control or Timer: (Right side of Dual Vat)

Note: This key has no function of single vat controls.

With display showing [PROGRAM], press the product key [0].

Display shows [SELECT] [OPTIONS].

Press product key 8; display will show [CONTROL].

Use the product key [0] to scroll through choices (Control, Timer).

Press [P] key to save choice. Display shows [PROGRAM].

Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions
active. Do not make this selection on Solstice fryer models.