WARNING!

Be sure to follow all applicable national and local electrical codes when
installing the electrical supply for this system. All field connections must be
liquid tight and readily accessible for inspection after installation without
moving the machine or its accessories. Personal injury, including serious
injury or death, and extensive equipment damage may result when proper
procedures are not followed. Do not attempt to energize this system
unless it is fully assembled with all protective features in place.

Electrical Power Requirements

The electrical power requirements of your new system are shown on the Power
Soak serial number plate located as follows:

• Mobile and free-standing stationary models—On the side of the control

enclosure which is attached to the motor

• Built-in models—On the side of the wash tank

Electrical Wiring Requirements

The wiring required for your system depends on the type of system you have
purchased:

• Mobile 115V units come equipped with a power cord and may be plugged into

any approved outlet rated for the amperage requirement stated on the Power
Soak serial number plate.

• Mobile 208V 1PH and 460V 3PH units must be connected to a wall-mounted

junction box, outlet, or disconnect by a licensed electrician. The wall-mounted
device must be NEMA 4X or IP67 rated and must be supplied by a dedicated
circuit.

• Free-standing stationary units must be connected to a wall-mounted junction box

or disconnect using water-tight flexible conduit by a licensed electrician. The
wall-mounted device must be NEMA 4X or IP67 rated and must be supplied by a
dedicated circuit.

• Built-in units must have their control box brackets mounted to the underside of

the dish table they are installed in. If no acceptable location exists on the
underside of the dish table, the control box may be mounted to the front of the
wash tank. To do this, remove the acorn nuts from the studs on the wash tank,
place the control box against the tank, and replace the acorn nuts. Once
mounted, jacketed cord must be installed between the control box and the motor
junction box and also between the control box and a wall mounted junction box
or disconnect. The wall-mounted device must be NEMA 4X or IP67 rated and
must be supplied by a dedicated circuit. All of these wiring tasks must be
performed by a licensed electrician.