INTRODUCTION

These installation, operation and maintenance instructions cover your electronic metering pump. Refer to the pump
nameplate to determine the actual model.

PRINCIPLE OF OPERATION

Diaphragm metering pumps are used to dispense chemicals or fluids. This is achieved by an electromagnetic drive
mechanism (solenoid) which is connected to a diaphragm. When the solenoid is pulsed by the control circuit, it
displaces the diaphragm which, through the use of check valves, moves the fluid out the discharge under pressure.
When the solenoid is de-energized it returns the diaphragm and pulls more fluid into the pump head and the cycle
repeats.

The stroke rate of the pumps is controlled via the touchpad and present status is indicated by the LCD display. The
stroke length is controlled via the stroke length knob.

MATERIALS OF CONSTRUCTION

The wetted materials (those parts that contact the solution being pumped) available for construction are Glass filled
polypropylene, PVC, SAN, Hypalon, Viton, PTFE, 316 Stainless Steel, PVDF, Ceramic and Alloy C. These materials
are very resistant to most chemicals. However, there are some chemicals, such as strong acids or organic solvents,
which cause deterioration of some elastomer and plastic parts, such as the diaphragm, valve seats, or head. Consult
Chemical Resistance Guide or Supplier for information on chemical compatibility.

Various manufacturers of plastics, elastomers and pumping equipment publish guidelines that aid in the selection of
wetted materials for pumping commercially available chemicals and chemical compounds. Two factors must always
be considered when using an elastomer or plastic part to pump chemicals. They are:

1. The temperature of service: Higher temperatures increase the effect of chemicals on wetted materials. The

increase varies with the material and the chemical being used. A material quite stable at room temperature
might be affected at higher temperatures.

2. Material choice: Materials with similar properties may differ greatly from one another in performance when

exposed to certain chemicals.

MA

NUFACTURER’S PRODUCT WARRANTY

Pulsafeeder warrants all pumps and controllers of its manufacture to be free of defects in material or workmanship.
Liability under this policy extends for 24 months from date of shipment from the factory.

The manufacturer’s liability is

limited to repair or replacement of any failed equipment or part which is proven defective in material or workmanship upon
manufacturer’s examination. This warranty does not include removal or installation costs and in no event shall the
manuf

acturer’s liability exceed the selling price of such equipment or part.


The manufacturer disclaims all liability for damage to its products through improper installation, maintenance, use or
attempts to operate such products beyond their functional capacity, intentionally or otherwise, or any other unauthorized
repair. The manufacturer is not responsible for consequential or other damages, injuries or expense incurred through the
use of its products.

Above warranty is in lieu of any other warranty, whether expressed or implied. The manufacturer makes no warranty of
fitness or merchantability. No agent of ours is authorized to provide any warranty other than the above.

The European Union Warranty address is listed below, however, please note that the seller should be contacted first.