Initial Prime, Continued…

System with Suction Lift

With a suction lift configuration, the
entire suction arrangement (suction
line and Skid suction piping) as well
as the pump must be purged of air
before the pump can function. The
pump can evacuate the air, however
this may take considerable time.

Optional:
If the dosing chemical can be
handled safely
, it may be helpful to
add dosing chemical to the suction
assembly via the top of the calibration
column. This requires the installation
of a foot valve at the entrance to the
suction line within the chemical
source container. Open the Air Bleed
Valve turning the opening knob
counterclockwise (see Figure 9).
Open Column Isolation Valve. Open
all valves in the Suction Line. Add
dosing chemical into the top of the
Calibration Column until liquid
remains visible. Follow steps, below.
Note that Air Bleed Valve is open.





1. Close Skid Discharge Valve and Column Isolation Valve
2. Open Air Bleed Valve (turn opening knob counterclockwise, see Figure 9)
3. Open all valve(s) on the suction side – Skid Suction Connection Valve and any valve(s) in your

suction line

4. Connect pump/motor to power source (pump/motor off)
5. Start pump using manufacturer’s recommendations for initial operation settings
6. Observe flow through Air Bleed Bypass. When solid stream (no air bubbles) is observed,

pump is primed.

7. Shut off pump.
8. Close Air Bleed Valve (turn opening knob clockwise)

Figure 11

Pump and Suction System Setup for Prime

Suction Lift Configuration

Chemical

Source

Suction Line

Pump

Skid Discharge
Connection/Valve

Column Isolation
Valve

Discharge Line

to Process

Skid Suction
Connection/Valve

Air Bleed
Bypass Line

Air Bleed
Valve

Calibration
Column

Advertising