Troubleshooting guide, Pre-engineered skid systems, Installation, operation and maintenance manual – Pulsafeeder Pre-Engineered Skid Systems User Manual

Page 22

Advertising
background image

Pre-Engineered Skid Systems

Installation, Operation and Maintenance Manual

PES00039, Rev. B

Troubleshooting

Page 22

Troubleshooting Guide



Problem

Possible Cause

Remedy


Pump doesn’t deliver product

Air entering suction line

Check fittings for tightness
Check integrity of tubing
Check level in suction source – must
be above foot valve at inlet

Air trapped in suction line

Re-configure suction line to eliminate
air pocket(s)

Suction line kinked or clogged

Inspect, replace tubing

Chemical source empty

Refill, re-prime pump

Pump not primed, air/gas in system

Re-prime pump

Air/gas bubbles forming in chemical

Reduce suction lift or change to
flooded suction
Consider chemical storage temperature

Strainer clogged

Check strainer, clean

Pressure Relief Valve open

Check Pressure Relief Valve integrity
Check Pressure Relief Valve setting

Pump problem(s) May be:
• Diaphragm wear, rupture
• Check valves worn or clogged

• Low pump flow setting
• Voltage/electrical difficulty

Refer to pump instructions.

Piping Vibration/chatter

Pulsation Dampener malfunction

Check Pulsation Dampener integrity
Check Dampener air pressure


Injection rate too high, too low

Pump output setting incorrect

Perform flow calibration

Chemical concentration too high, low

Adjust chemical source strength

Siphoning into well or low pressure
point

Add Back Pressure Valve at injection
point

Injector clogged, scaled, restricted

Check injector for solids or corrosion
Clean as necessary or replace

Injection rate varies

Back Pressure Valve

Check Back Pressure Valve integrity
Check Back Pressure Valve setting

Tubing failure

Sunlight/UV exposure

Change to UV-resistant tubing

Corrosive attack

Determine material compatibility,
change as necessary

Leaky fittings

Loose fittings

Tighten fittings – plastic fittings should
be hand-tight only

Corrosive attack

Determine material compatibility,
change as necessary


If problem(s) persist, call your Pulsafeeder representative. We’re here to help.