Vaddio DomeVIEW Outdoor Pendant Mount User Manual

Page 5

Advertising
background image

Vaddio DomeVIEW Outdoor, Environment Pendant Mount Dome Installation and User Guide - Document 341-445 Rev C

Page 5 of 14


6) The heater/blower circuit card (Figure 5) receives

power from the included 24 VAC power supply.

This

power supply powers the fans and heater strip only.

The

24 VAC output is not used with Vaddio camera
systems. The video in and out is not used with
Vaddio EZCamera cabling systems.

A. The 24 VAC power supply is connected to

the AC terminals (24 VAC IN) on the circuit
board to power both the heater and the fan.

B. Connect the heater strip and fan connectors

on the circuit board.

C. Pull the camera cabling through the center

or backside of the mounting plate making
sure that the cabling does not contact the
heater strip.

D. Re-install the mounting plate inside the

dome. Tighten down the three screws
making sure the safety tether and all other
cables are tucked up behind the mounting
plate to avoid interference with the PTZ
camera movement.


NOTE: the Power supply for the heater/blower must be
located within 100’ (30.48m) of the dome enclosure.




7) The camera brackets are attached to the

heater/blower mounting plate through two (2) ¼”
threaded holes on the plate labeled F (Figure 6).
For all mounts the hex shaped stand-offs are ¼”-
Male to 8-32-Female with the length of the stand-off
determining the height of the camera in the dome.


8) See Figure 7, thread the stand-offs (7) into the F-

holes in the mounting plate inside the dome (8) and
attach the camera mounting stage (6) to the stand-
offs with the 8-32 x .5” flat head screws (5).










Canon VC-C50iR Camera Only (Figure 7 on the following page)


9) Attach the EZCamera Cabling Shoe (4 - Figure 7) to the Canon VC-C50iR (DomeVIEW 50iR Outdoor

Pendant Dome only).

A. When mounting the Canon VC-C50iR without the EZCamera Cabling System – skip this step.

10) Attach the camera (3) to the camera mounting stage (6) with two 8-32 x .5” pan head screws (2) and two

#8 lock washers (see Figure 5). Skip to Step 15.


Figure 5:
Heater/blower circuit with connections, Use 2-cond 18AWG
unshielded cable and locate power supply within 100’ (30.48m
of the dome enclosure). The 24VAC OUT is not used.

Figure 6:
Two (2) ¼”-Male to
8-32 Female
standoffs mount to
holes marked “F”

Back

Front

Note:
Only one (1) fan
will be mounted
to this plate

Advertising
This manual is related to the following products: