NOTES:

1. There is no valid DMX-512 address 0. To make the LP-DMX3/

LP-DMX5 work for those who might not want to read the manual,
we promoted address switch setting 0 to access DMX channel 1.

2. Some controllers have DMX addresses above 512. These are

actually addresses 1-512 on a second cable (referred to as a second
DMX universe). There is no provision for the LP-DMX3/LP-
DMX5 to span universes.

3. In mode 1, setting the DMX start channel higher than 509 will

result in the loss of functionality of one or more LED pods. In
mode 2, setting the DMX start channel higher than 505 will result in
the loss of functionality in some pods. In mode 3, setting a start
channel higher than 501 will result in the loss of functionality in
some pods. In mode 4, setting a start channel higher than 493 will
result in the loss of functionality in some pods.