6 remote power out, 7 ac power out, Remote power out – Beijer Electronics MTe Nautic EN User Manual

Page 18: Ac power out

Advertising
background image

Description of Parts

18

Beijer Electronics, MAEN983B

5.6 Remote Power Out

Remote power out is a relay contact that is closed after the power button on the
front side is pressed for more than one second. It is opened after the button is
released. With the remote power out signal, it is possible to switch an external
Beijer Electronics EPC Nautic on and off. The EPC has a corresponding ATX
power remote input. To use this function, connect the double-pole Phoenix con-
nector to the corresponding connector on the EPC.

5.7 AC Power Out

The AC power out terminal on the 230 V AC-models is internally connected to
the AC power in terminal through a double-pole relay. This makes it possible to
connect an external AC powered device such as a PC (max. 6 A). The AC power
out is active only when the monitor is on.

Advertising