Enabling Switch

16

Beijer Electronics, MAEN843A

6

Enabling Switch

The M70 is equipped with two enabling switches, one at the left and one at the
right side of the device. This allows a left- and right-hand operation of the en-
abling switch. Both enabling switches are equivalent and parallel switched,
which means that for enabling, only one of both enabling switches must be ac-
tivated.

Please see chapter

1 Safety Precautions

for safety precautions regarding enabling

switches.

The enabling switch consists of a 3-position operating element and an separated
evaluation electronics. An essential feature are the continuous two-channel
circuits beginning from the actuating elements up to the connecting terminals.
For the evaluation circuits different technologies and circuits are used. Due to
the electronic switching contacts, their lifetime does not depend on the load pro-
vided the nominal values of the load (ohmic, inductive and capacitive) are not
exceeded.

The switching elements of the enabling switches are protected against reversed
polarity. The outputs of both circuits are protected against short circuits and
overload.
Circuit 1: thermal protective circuit
Circuit 2: fold back line

The actuating element consists of two symmetrically arranged slides. The posi-
tion of these slides is detected by electrical switches and transmitted to the eval-
uation electronics.

Positions of enabling switch:

Note:

The enabling switches are hardware dependent, and are separated from the soft-

ware running in the operator panel. The panel will function normally, regardless of

the status of the enabling switches.

Position

Function

Enabling switch

Contacts

1

Home position Not pressed

Enabling outputs are open

2

Enabling

Pressed

Enabling outputs are closed

3

Panic

Pressed strongly

Enabling outputs are open