Fagor 2MCF-2GSAXBUT User Manual
Page 13
1/ INSTALLING YOUR APPLIANCE
13
EN
•
Adjust the hob connections: these are
located underneath the control knobs
(Fig. 04).
— Proceed one tap at a time.
— Remove the control knobs and the gaskets
by pulling upwards.
- Switching from natural gas to
butane/propane
-
Using a small flat-head screwdriver, fully
tighten the brass burner power screws
(yellow)
(Fig. 05), in a clockwise direction.
-
Replace the gaskets and the control knobs,
noting their direction and ensuring that the
control knobs are fully inserted.
- Switching from butane/propane to natural
gas
-
Unscrew the brass (yellow) burner power
screws
(Fig. 05), using a small flat-head
screwdriver, turn twice anti-clockwise.
-
Replace the control knob.
-
Ignite the burner in maximum heat mode,
then turn down to reduced heat mode.
-
Remove the control knob again, then turn
the burner power screw clockwise until it
reaches the lowest possible setting without
extinguishing the flame.
-
Replace the gasket and control knob.
-
Repeatedly change from the maximum to
the minimum flow rate: the flame must not go
out ; if it does, unscrew the burner adjustment
screw to achieve good flame retention during
these changes.
-
Replace the burner heads, burner covers
and pan supports on the hob.
Sealing ring
Tap
Fig. 04
Fig. 05
Tap axis
Burner power
adjustment screw
Control Knob