Adjust for Make Up

2. Measure the tool joint with OD

calipers.

3. Use the 1 1/2" wrench to adjust

the Pointer (P) on the Pipe stop
index
(PI) to the OD tool joint
size. Its always better to adjust the
pointer 1/4" to 1/2" larger than
the measured diameter of the
tool joint.

4. For safety, adjust the Bottom

wrench nut (BN) 1" larger than
the Top wrench nut (TN) and
Middle wrench nut (MN).

5. Rotate the Top wrench nut (TN)

and the Middle wrench nut (MN)
to the OD tool joint size. Visually
align the end face (F) of the
wrench nut with the scale (S) on
the wrench.

Operation

Shown set for 6 " OD tool joint

Shown set for 6" OD tool joint

S

F

BN

MN

TN

P

PI

16

Operation