Air power pack maintenance – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 206 to 591 User Manual

Page 36

Advertising
background image

36

Maintenance & Repair

1. The hydraulic tank should be

cleaned approximately once

every year of service.

2. Remove the lock strap from

the tank valve (TV) and rotate

clockwise to the off position.

2. Drain the hydraulic tank first by

removing the pump end of the

pump suction hose (PSH). Ro-

tate the tank valve (TV) to the on

position and drain off old oil.

3. Unscrew the other end of the

pump suction hose from the tank

valve (TV), and remove the tank

valve and the suction strainer

inside the tank, by unscrewing

the tank valve at the fitting (TF)

just adjacent to the tank.

4. Thouroghly clean the suction

strainer (SS) with cleaning sol-

vent. Replace if damaged.

5. Flush out the tank with cleaning

solvent and remove sludge build-

up on the bottom of the tank.

6. Re-install all components.

7. Replace return line filter. See

prior page.

8. Fill the tank with clean oil.

9. Make sure the tank valve (TV) is

turned on (the position shown in

above photo). Lock the valve in

the on position with wire.

Change Suction Strainer

PSH

TF

TV

Air Power Pack Maintenance

Part Name

Part #

Suction Strainer (SS)

031-P04A

Part Numbers

SS