Pan Mode Positive: Normal operation: When you press the Pan1 and Pan2, their starting

off point of Pan will be different.

2- Pan Mode Negative: (mirror image); the Starting -off point of Pan1 = the end-point of Pan2

the Jumping-off point of Pan2 = the end-point of Pan1.

3- Tilt Mode Positive: Normal operation: When you press the Tilt 1 and Tilt 2, their starting

off point of Tilt will be same.(seldom ever used)

4- Tilt Mode Negative: Also same as Pan. (seldom ever used)

5- LED Positive Display: When leaving on floor mounted or on test bench (as shown)

6-

LED Negative Display When you reverse the unit, if you make "LED Negative Display",

then it's more convenient to see the display when upside down and mounted.

For address setting,

Press the Mode-button until the display shows "d" and set the desired base address via
the Up / Down-buttons.


Controlling:

After having addressed all PROMOVER 575 you may now start operating these via your
lighting controller.
Note: After switching on, the PROMOVER 575 will automatically detect whether DMX 512
data is received or not. If the data is received, the control LED flashes. If there is no data
received at the DMX-input, the control LED lights up permanently.
This situation can occur if:

-

The 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input
of the PROMOVER 575 or having a bad connecting cable

-

The controller is switched off or defective, if the cable or connector is defective or the
signal wires are swapped / reversed in the input connector.
Note: It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in
the link in order to ensure proper transmission on the DMX data link.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are
Inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are
inspected by a skilled person once a year.

The following points have to be considered during the inspection:

1) All screws used for installing the devices or parts of the device have to be tightly
connected and must not be corroded.
2) There must not be any deformations on housings, fixations and installation spots
(ceiling, suspension, trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of
wearing (e.g. material abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g.
porous cables) or sediments. Further instructions depending on the installation spot and
usage have to be adhered to by a skilled installer and any safety problems have to be
removed.
-

Disconnect from mains before starting maintenance operation!