Meteor ProMover 575 User Manual

Page 5

Advertising
background image

5

DESCRIPTION OF THE DEVICE:

Features:

Innovative Professional scanner with rotating gobos

16 different, dichroic color filters and white

Rainbow-effect with adjustable speed in both directions

Gobowheel with 14 rotating gobos, open and blackout

Strobe-effect with adjustable speed (1-10 flashes/sec.) via shutter

DMX-controlled operation or stand alone operation with Master/Slave-
function

Sound-controlled via built-in microphone

Fuzzy-Sound-Control: program continues automatically during periods
without music or bass-beat

Control-Board with 4-digit LCD display

Digital DMX focus

For HMI 575

Actual Lamp Hours – User time.

DMX-control via every standard DMX-controller

14 DMX-control channels required


DANGER TO LIFE:
-

Only install the lamp with the device switched off. And not plugged into power

-

Always unplug power from mains before attempting any service.

-

For the installation, you need one HMI 575. Do not touch glass part of lamp.

-

The lamp must only be changed when wearing appropriate protective clothing (protection
glasses, protection gloves, helmet with sight, leather apron).


INSTALLATION

Installing/Replacing the lamp Procedure:
CAUTION!

-

The lamp has to be replaced when it is damaged or deformed due to the heat!

-

The lamp life given by the manufacturer must never be exceeded. This is why you need to
take notes on the operational time of the lamp and replace the lamp in time.

-

Keep exchanged lamp in a protective container and remove accordingly.

-

During the operation, the lamp reaches temperatures of up to 600° C.

-

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10
minutes).

-

During the installation do not touch the glass-bulbs barehanded!

-

Please follow the lamp manufacturer's notes!

-

Do not install lamps with a higher wattage! Lamps with a higher wattage generate
temperatures the device was not designed for.

-

Damages caused by non-observance are not subject to warranty.


Step 1: Unscrew the 4 Phillips screws on back plate. Unscrew 4 Phillip head screws that hold
lamp housing system to fixture and carefully remove it from the housing.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder. Make sure lamp is properly secured in brass fitting.
Step 4: Replace the lamp system in the housing and tighten the fixation screws.
Step 5: Adjust the lamp as described under lamp adjustment.

Do not operate this device with opened cover!

Advertising