Installation

MKG Series Gas Griddle

L25-055 Rev. 0 (05/12)

6

Figure 2

Figure 3

Pleasant Valley Rd., Cleveland, OH 44131. In Australia, the ventilation system must comply with AS/NZS
5601.1.

CAUTION

Excessive ventilation causes drafts, which will interfere with the operation of the appliance. Leave

at least 18 inches of open space between the flue opening and the intake of the exhaust hood.

CAUTION

Ensure that your ventilation system does not cause a down draft at the appliance’s flue opening.

Down drafts will not allow the appliance to exhaust properly and will cause overheating which

may cause permanent damage. Damage caused by down drafts will not be covered under

equipment warranty. NEVER allow anything to obstruct the flow of combustibles or ventilation

exiting the appliance flue.

1.6. Installation

Setup

The installation of this appliance MUST conform to
local codes. In the absence of local codes in North
America, the installation must conform with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 or
the Natural Gas and Propane Installation Code
CSA B149.1 as applicable. In Australia, the
appliance must installed in compliance with
AS/NZS 5601 (current revision).
To Start uncrate appliance and locate installation
accessories.

1.6.1. Counter Use With Legs

CAUTION

To prevent equipment damage, DO NOT tilt

your MagiKitch'n griddle on only two legs, or

on its sides.

(See Figure 2) A set of 4” (10.2cm) legs is
shipped with the appliance (unless appliance
was specifically ordered without legs). A
threaded insert for the leg bolt is located near
each corner of the bottom appliance. Raise the
appliance to allow legs to be screwed tightly into
inserts. The appliance can be leveled by
adjusting the feet at the bottom of the leg
assembly. This can be done by turning the foot
in or out to lower or raise each corner as
needed.

NOTICE

4" Legs should not to be used with the

Equipment Stand.

1.6.2. Counter Use Without Legs

See Figure 3) The appliance must be sealed to the
counter to comply with applicable sanitation
standards. A bead of silicone sealant,
approximately ½ inch (13 mm) wide, is to be
applied to the bottom of the unit approximately ¼”
(7 mm) in from the front, back and side edges. We
suggest Dow Corning ® 732 silicone ‘RTV’
adhesive sealant or equivalent. (See NSF Basic
Criteria C-2 for details).

WARNING

DO NOT alter or remove structural material

on the appliance to accommodate placement

under a ventilation hood.

Advertising