5.H

ANGING THE

F

AN

REMEMBER to turn off the power.

Follow the steps below to hang your

fan properly:

Step 1. Secure the hanger bracket to

the ceiling outlet box using screws

included with your outlet box, lock

washers included with the fan. (Fig.8)

Step 2. Loosen the two set screws and

remove the hitch pin and lock pin in

the top coupling of the motor

assembly. (Fig. 9)

Step 3. Remove hanger ball from

downrod assembly by loosening set

screw, removing the cross pin, and

sliding ball off rod. (Fig.10)

Step 4. Carefully feed fan wires up

through the downrod. (Fig. 11)

Thread the rod into the coupling,

next line up holes and replace lock

pin and hitch pin. Tighten set screws.

Step 5. Slip coupling cover, canopy

cover and canopy onto downrod.

(Fig. 12) Carefully reinstall hanger

ball onto rod being sure that cross pin

is in correct position, set screws are

tighten and wires are not twisted.

Step 6. Now lift motor assembly

into position and place hanger ball

into hanger bracket. Rotate until the

check groove has dropped into the

registration slot and seats firmly. (Fig.

13) Rod should not rotate if this is

done correctly.

Outlet box

Hanger bracket

Downrod

Supply

wires

Figure 8

Figure 10

Figure 11

Figure 9

Figure 12

Figure 13

Downrod

Coupling

*Omit coupling

cover when

downrod

cover

using

the minimum-length

Canopy

Canopy cover

Set screws

Hitch pin

Lock pin

Registration

slot

Cross pin

Hanger

ball

Downrod

Hitch

pin

Lock

pin

Set

screws

Screw