6

Installation/Commissioning

DANGER

Only install or uninstall the switch when de-energized (electrically and hydraulically/pneumatically).

Process connection and electrical connection must be carried out by trained or instructed
personnel according to state-of-the-art standards.

The switch must only be installed in systems where the maximum temperature T

max

is not

exceeded (see type label).

WARNING

Be aware of the fact that in case of operation with higher temperatures the casing surface may
become very hot!

Ambient temperature range: –40… +75 °C; max. pressure at sensor: 21 bar

WARNING

In case the temperature falls below or exceeds the permissible temperature limits specified for the
sensor and the permissible ambient temperature, the function of the temperature switch can no
longer be guaranteed and the temperature switch may be damaged.

Check the operation of the switch regularly. If the switch does not work properly, stop operation
immediately!

CAUTION

All standard temperature switches are supplied with conduit threads which must be sealed with
pipe sealant or Teflon tape to prevent moisture entry. The explosion-proof switches have threaded
plugs covering the electrical connection entry.

Threaded plugs must be removed to install the approved electrical connection of your choice.

The capillary system must be installed with care avoiding sharp bends.

Provide protection against damage where needed.

IMPORTANT

The temperature sensing element can be used up to 21 bar. In case of pressures higher than 21
bar the temperature sensing element must be provided with a thermowell suitable for the
respective application.

All temperature switches are tested for proper functioning before they leave the factory.

Electrical Ratings

Micro
switch

Special
Characteristics

Volt AC
50/60 Hz

Ind.
Load
A

Res.
Load
A

Volt DC

Ind.
Load
A

Res.
Load
A

Notes

H

Micro switch with
silver contacts

125
250
480

10
10

3

10
10

3

6
to
24


0.50


0.5

Small hysteresis;
high AC / low DC
loads

M

Micro switch with
silver contacts

125
250
480

10
10

3

10
10

3

12
24
250

5.00
1.00
0.25

15.0
2.0
0.4

Medium hysteresis;
high AC and DC
loads

GH

Micro switch with
gold plated
contacts for low
voltage and low
current

125

1

1

24

1.00

1.00

Small hysteresis

S

Micro switch with
silver contacts

125
250
480

15
15
15

15
15
15

12
24
250

10.00
5.00
0.03

15.0
6.0
0.2

Adjustable
hysteresis

J

Micro switch -
sealed - with
silver contacts

125
250
480

10
10

3

10
10

3

6
to
24


0.50


0.5

Small hysteresis

G…RD

Micro switch with
silver contacts

125
250
480

10
10
10

10
10
10

12
24
250

15.00
10.00
0.20

15.0
15.0
0.3

Manual reset

We recommend gold plated contacts for all applications with low voltage/power.

IMPORTANT

Data only valid for application in non-explosive atmosphere.

We recommend use of a pre-fuse of the maximum current rating from the table above according to the
load switched.