b. Dual Timer Dryers

1) Spin and dwell (stop) times are adjustable at the reversing timer.

BASKET (TUMBLER) COATING

The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material
with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove
this coating.

8. Each dryer should be operated through one (1) complete cycle to assure that no further adjustments are

necessary and that ALL components are functioning properly.

9. Make a complete operational check of ALL operating controls.

a. Microprocessor controller (computer) programs and selections...

1) Each microprocessor controller (computer) has been preprogrammed by the factory with the most

commonly used parameter (program) selections. If computer program changes are required, refer
to the computer programming manual, which was shipped with the dryer.

b. Dual timer dryers check...

1) Heating Timer

2) Cool Down Timer

3) Temperature Selection Switch

K. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2. Discontinue the heat supply:

a. GAS MODELS...discontinue the gas supply.

1) SHUT OFF external gas supply shutoff valve.

2) SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.

b. STEAM MODELS...discontinue the steam supply.

1) SHUT OFF external (location furnished) shutoff valve.

2) SHUT OFF internal steam valves in the supply lines and the return lines.