Australian Monitor AMC+MIX User Manual

Page 2

Advertising
background image

1. Save the carton and packing material even if the equipment has arrived in

good condition. Should you ever need to ship the unit, use only the original
factory packing.

2. Read all documentation before operating your equipment. Retain all

documentation for future reference.

3. Follow all instructions printed on unit chassis for proper operation.
4. Do not spill water or other liquids into or on the unit, or operate the unit

while standing in liquid.

5. Make sure power outlets conform to the power requirements listed on the

back of the unit.

6. Do not use the unit if the electrical power cord is frayed or broken. The

power supply cords should be routed so that they are not likely to be
walked on or pinched by items placed upon or against them, paying
particular attention to cords and plugs, convenience receptacles, and the
point where they exit from the appliance.

7. Always operate the unit with the AC ground wire connected to the

electrical system ground. Precautions should be taken so that the means
of grounding of a piece of equipment is not defeated.

8. Mains voltage must be correct and the same as that printed on the rear of

the unit. Damage caused by connection to improper AC voltage is not
covered by any warranty.

9. Have gain controls on amplifiers turned down during power-up to prevent

speaker damage if there are high signal levels at the inputs.

10. Power down and disconnect units from mains voltage before making

connections.

11. Never hold a power switch in the “ON” position if it won’t stay there itself!
12. Do not use the unit near stoves, heat registers, radiators, or other heat

producing devices.

13. Do not block fan intake or exhaust ports. Do not operate equipment on a

surface or in an environment which may impede the normal flow of air
around the unit, such as a bed, rug, weather sheet, carpet, or completely
enclosed rack. If the unit is used in an extremely dusty or smoky
environment, the unit should be periodically “blown free” of foreign matter.

14. Do not remove the cover. Removing the cover will expose you to potentially

dangerous voltages. There are no user serviceable parts inside.

15. Do not drive the inputs with a signal level greater than that required to

drive equipment to full output.

16. Do not connect the inputs / outputs of amplifiers or consoles to any other

voltage source, such as a battery, mains source, or power supply,
regardless of whether the amplifier or console is turned on or off.

17. Do not run the output of any amplifier channel back into another channel’s

input. Do not parallel- or series-connect an amplifier output with any other
amplifier output. Australian Monitor Inc is not responsible for damage to
loudspeakers for any reason.

18. Do not ground any “hot” terminal. Never connect a “hot” output to ground

or to another “hot” output!”

19. Non-use periods. The power cord of equipment should be unplugged from

the outlet when left unused for a long period of time.

20. Service Information Equipment should be serviced by qualified service

personnel when:
A. The power supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the equipment
C. The equipment has been exposed to rain
D. The equipment does not appear to operate normally, or exhibits a
marked change in performance
E. The equipment has been dropped, or the enclosure damaged.

21. Heed all Warnings.
22. Do not use this apparatus near water.
23. Clean only with a dry cloth.
24. Do not block any ventilation openings. Install in accordance with the
25. Do not defeat the safety purpose of the polarized or grounding - type plug.

type plug has two blades and a third grounding prong. The wide blade or
fit into your outlet, consult an electrician for replacement of the obsolete
outlet.

26. Protect the power cord from being walked on or pinched particularly at

plugs, convenience receptacles ,and the point where they exit from the
apparatus.

27. Only use attachments/accessories specified by the manufacturer.
28. Use only with a cart, stand, tripod, bracket, or table

specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/
apparatus combination to avoid injury from tip-over.

29. Unplug this apparatus during lightning storms or when

unused for long periods of time.

30. The AC/AC adaptor and apparatus shall not be exposed to dripping or

splashing and that no objects filled with liquids, such as vases, shall be
placed near apparatus.

L’ adaptateur AC/AC de l’appareil ne doit pas être obstruè ou doit être
facilement accessible pendant son utilisation. Pour être complétement
dèconnectè de l’alimentation d’entrèe, l’adaptateur AC/AC de l’appareil
doit être dèconnectè du secteur.

31. Mains plug is used as disconnect device and it should remain readily

operable during intended use. In order to disconnect the apparatus from
the mains completely, the mains plug should be disconnected from the
mains socket outlet completely.

La prise du secteur est utilisè pour dèconnecter le systéme. La prise du
secteur ne doit être obstruèe ou doit être facilement accessible pendant
son utilisation. Pour être complétement dèconnectè de l’alimentation
d’entrèe, la prise doit être dèbranchèe du secteur.

32. To be completely disconnect the power input, the mains plug of AC/AC

adaptor shall be disconnected from the mains .

33. A minimum distance of 5mm around the apparatus for sufficient

ventilation should be provided.

34. The ventilation should not be impeded by covering the ventilation opening

with items such as newspaper, table-cloths,curtain etc.

35. No naked flame sources such as lighted candles should be placed on the

apparatus .

36. This product is designed for moderate climates only.

IMPORTANT SAFETY INFORMATION

PRÉCAUTIONS DURANT UTILISATION

Advertising