PACKAGED TERMINAL A/C

OWNER’S MaNual

Heat Controller

3

Fan Motors Permanently Lubricated - All units

have two fan motors for quiet operation and

maximum operating efficiency.

Motors are permanently lubricated to reduce

maintenance and totally enclosed to keep dirt and

water out of the motor windings.

Indoor Fan Speed Selections LOW /HIGH - Unit

may be operated in low fan speed or high fan

speeds. Some speeds may not be present based

on unit capacities.

Rotary Compressor - smoother operation for quiet,

dependable service and high efficiency.

Indoor Coil Frost Control - prevents indoor coil

from freezing. Frost can form on the Indoor coil

when the unit is operated in cooling when the

outdoor temperature is low. The unit automatically

shuts the compressor off until the indoor coil

temperature warms to the point where frosting will

no longer occur, then restarts the compressor.

LS Control (front-desk control) - The unit can

be turned ON/OFF by a front desk control switch.

The control wire, colored purple, locates in the wall

mounted thermostat interface (refer to Fig. 7 on

page 8).

The control logic as belows:

1. Turn ON unit: short circuit R and LS then release

one time within 5 seconds.

2. Turn OFF unit: short circuit R and LS then release

for twice within 5 seconds.

3. Force unit shut down for one time: connect LS to R

for over 5 seconds.

NOTE: After force shut down, you can turn the unit

ON again by hand-held remote controller or the

control panel.

Special control functions for DIP switches - The

DIP switches are on main board. No. 5 auto

heating (for units with heat). When unit is connected

to the power supply, and room temperature Is

lower than 10°C/50°F for 3 minutes, unit will start

heating automatically no matter what the setting

mode is. Only when room temperature reaches

13°C/55°F will heating stop.

ON position enables this function.

No. 6 -Electric Power-off Memory. After power on,

the unit will run the same settings as last time.

ON position enables this function. No. 7-Fan

CON/CYC for heating.

ON position enables continuous fan for heating. The

default setting Is fan cycled for heating.

No. 8 -Fan CYC/CON for cooling ON position

enables fan cycle for cooling. The default setting is

fan continuous for cooling.

WARNING: Before service, you must disconnect

the power cord to avoid electric shock! Do not

reprogram DIP switches No. 1 to No. 4, when

powered this could cause damage or fire. Power the

unit on again, the new function will be activated.

UNIT ACCESSORIES

This unit is designed for through-the-wall installation

in new or existing buildings. To complete the

installation of this PTAC, an insulated wall sleeve and

an outdoor grille (either the stamped aluminum

grille, or the architectural grille) are required.

Consult with your distributor to acquire any optional

accessories.

The chassis and the cabinet front are shipped in one

carton.

WARNING

HIGH VOLTAGE

DISCONNECT ALL POWER BEFORE SERVICING

OR INSTALLING THIS UNIT. MULTIPLE POWER

SOURCES MAY BE PRESENT,FAILURE TO DO SO

MAY CAUSE PROPERTY DAMAGE,PERSONAL

INJURY OR DEATH.

!