PACKAGED TERMINAL

OWNER’S MaNual

Heat Controller

7

WIRING

Cord connection to a wall socket is not permitted for

265V units. All 265V units must be hard wired using

the hard wire kit or make use of the plug in receptacle

in the standard subbase.

230~208V units are equipped with LCDI power cords

and can open the electrical circuit to the unit. In

the event the unit does not operate, check the reset

button located on or near the head of the power cord

as part of the normal procedure.

VOLTAGE MEASUREMENTS

Once the unit is properly wired, measure the unit

supply voltage. Voltage must fall within the voltage

range given in Chart 3.

Fig. 6 Receptacles / Sub-bases

NOTE: See the “Remote Thermostat Change”

Instructions before using the thermostat.

Fig. 7 wall mounted thermostat wiring

Operating Voltage

Unit Voltage

Voltage Utilization Range

Rating

Minimum

Minimum

230/208

187

253

265

238

292

Chart 3 - Operating Voltage

WARNING

HIGH VOLTAGE

DISCONNECT ALL POWER BEFORE SERVICING OR

INSTALLING THIS UNIT MULTIPLE POWER SOURCES BE

PRESENT, FAILURE TO DO SO MAY CAUSE PROPERTY

DAMAGE, PERSONAL INJURY OR DEATH.

DO NOT SERVICE THIS UNIT WITHOUT FIRST SHUTTING

OFF THE POWER TO THE UNIT FROM THE CIRCUIT

BREAKER AND/OR REMOVING THE UNIT CORD SET PLUG

FROM THE WALL OUTLET.

!

WARNING

TO AVOID THE RISK OF PROPERTY DAMAGE, PERSONAL

INJURY OR FIRE, USE ONLY COPPER CONDUCTORS.

!

WARNING

TO AVOID THE RISK OF PROPERTY DAMAGE, PERSONAL

INJURY OR DEATH DUE TO ELECTRICAL SHOCK, DO NOT

USE AN EXTENSION CORD WITH THIS UNIT.

!

WARNING

TO AVOID THE RISK OF PROPERTY DAMAGE, PERSONAL

INJURY OR FIRE. DO NOT INSTALL WITH POWER CORD

STRETCHED OR UNDER A STRAIN AS THIS MAY CREATE

LOOSE PLUG/RECEPTACLE CONNECTION.

!

WARNING

TO AVOID THE RISK OF PERSONAL INJURY, WIRING TO THE

UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.

!

WARNING

THIS AIR CONDITIONER IS NOT MEANT TO PROVIDE

UNATTENDED COOLING OR LIFE SUPPORT FOR PERSONS

OR ANIMALS WHO ARE UNABLE REACT TO THE FAILURE

OF THIS PRODUCT.

THE FAILURE OF AN UNATTENDED AIR CONDITIONER MAY

RESULT IN EXTREME HEAT IN THE CONDITIONED SPACE

CAUSING OVERHEATING OR DEATH TO PERSONS OR

ANIMALS.

!

265V 30 Amp

265V 20 Amp

Large tandem

230/208V 30 Amp

Perpendicular

230/208V 20 Amp

Thermostat