RMS Technologies R208 DRIVER User Manual

Page 13

Advertising
background image

RMS Technologies

Page 13

Version 1.22

R208 Microstepping Driver Manual

8/31/2007

Internal Schematic

The R208 has 3 optically isolated logic inputs. These inputs are isolated to minimize or
eliminate electrical noise coupled onto the drive control signals. Each input is internally

pulled-up to the level of the optocoupler supply and may be connected to sinking outputs on
a controller or a PLC. These inputs are:


Enable/Disable (Pin 4)

Direction (Pin 5)

Step Clock (Pin 9)


Figure 6: Optically Isolated Inputs


Within the Driver lies three 680 Ω

Resistors and three Optocouplers.

The current is limited to 7 mA due to

these three Opto Couplers.

Resistor Values for the Opto Supply

The optocouplers must be powered by an external power supply to maintain
isolation. The Opto Supply for the optocouplers can be between +5 to 24 VDC with

respect to the signal input. It is recommended to use a +5 VDC Opto Supply in
order to limit the current going into the optocouplers to 10 mA. However, if the
supply is greater than +5 VDC then a resistor must be connected in series with each

signal line to maintain 10 mA of current running through the optocouplers. Do NOT
provide more than 10 mA or damage may occur to the driver.
Refer to Table 7

& 8 for the corresponding Resistor Values.

The Resistors shall be connected in series with each Input: Pin 4 (Disable), Pin 5 (Direction),
and Pin 9 (Step).


Step & Direction lines have a 470 ohm internal resistor

Voltage:

5V

10V

15V

24V

Ohms needed:

0 500 1000 2000

Wattage rating:

0

¼ watt

¼ watt

½ watt


Disable line has a 680 ohm internal resistor

Voltage:

5V

10V

15V

24V

Ohms needed:

0 750 1500 2700

Wattage rating:

0

1/8 watt

¼ watt

½ watt

Table 7 & 8: Resistor Values for inputs

Advertising