RMS Technologies R208 DRIVER User Manual

Page 15

Advertising
background image

RMS Technologies

Page 15

Version 1.22

R208 Microstepping Driver Manual

8/31/2007

Figure 7.3: 6 Lead Wire Full Winding Connection


8 Lead Wire Motor Connection (Parallel Connection)

Eight wire motors can be connected in two ways: Parallel and Series. When in
parallel, the wires are simply connected such that the beginning of each winding are
connected together.

Figure 7.4: 8 Lead Wire Parallel Connection


8 Lead Wire Motor Connection (Series Connection)

Be sure to set the drive current to exactly half of the motor’s rated parallel current
rating when using the series connection.

Figure 7.5: 8 Lead Wire Series Connection