09/15/2005

6 Lead Wire Motor Connection (Full-Winding)
For a full winding connection, use both end wires, the center tap is ignored. (NC: No

Connection).

Figure 9.3: 6 Lead Wire Full Winding Connection

8 Lead Wire Motor Connection (Parallel Connection)
Eight wire motors can be connected in two ways: Parallel and Series. When in

parallel, the wires are simply connected such that the beginning of each winding are
connected together.

Figure 9.4: 8 Lead Wire Parallel Connection


8 Lead Wire Motor Connection (Series Connection)

Be sure to set the drive current to exactly half of the motor’s rated parallel current
rating when using the series connection.

Figure 9.5: 8 Lead Wire Series Connection