R164 Controller will accept commands, but the Motor will stall in the middle
of a command:


This means there is not enough current being supplied to the Motor. Use the m and l

(lower case L) commands to change the current, or run the Motor at a Lower Speed
(V command).


Halt Command (H01) Issues

There are known issues involving the Halt command (i.e., H01) when stored in

memory location zero. Upon power up, the remaining command string after the Halt
command might be executed if the user types in a new command. If memory

location zero is not being used, the user is advised to always clear everything in
memory by typing /1?9. Otherwise, the user may terminate the remaining

command string in the buffer by issuing a /1T.


I want to use one of the I/Os to turn on a LED to confirm that the motor has
finished moving or moved to a certain position. How do I do it?

To turn on a LED to confirm that the motor finished moving you must use the “J”
command in the command list section On/Off Drivers. We are assuming the unit

executes the command sent. We cannot detect skipping because the set up is open
loop. Example: /1P200J10R , is a position move 200 steps, then turn on driver 2.


What’s the minimum and maximum voltage the RS485 to RS 232 Converter

Card can handle?
Min and Max voltage levels: 7 to 40 VDC


Using a PLC to communicate with board

After the command, you need to issue a carriage return and linefeed.

Example: /1A1000R (absolute position move 1000). After the R, send a 0x0d

in hex.