InBox / OutBox

User Manual

 Attero Tech LLC 2010

Page 26

614-00005-04

7.5 – OutBox R8

The CobraNet interface unit shall provide eight single-ended outputs on front panel with RCA connectors. The internal
digital to analog signal conversion shall be performed at 24-bit resolution with a sampling frequency of 48 kHz. The
CobraNet interface unit shall receive power over the Ethernet cable from an 802.3af PoE compliant network switch. The
CobraNet interface shall be wall mounted in a standard dual gang junction box.

The CobraNet interface shall be compatible with Attero Tech Control Center software for flexible control and monitoring in
system applications. The CobraNet interface shall be compliant with the RoHS directive.

The CobraNet interface shall be the Attero Tech OutBox R8.

7.5.1 – OutBox R8 Device Specifications

CobraNet Network

Physical Level:

Standard Ethernet

Connector:

Single RJ-45

Cable Quality:

CAT-5

Transmission Speed:

100 Mbps

Power Requirements

48V via 802.3af PoE
compliant Ethernet switch

Power Consumption

4W

Dimensions

Main Unit: 3.59” x 2.72” x
1.965” (w x h x d)

Weight

0.75 lbs

Compliance

RoHS, FCC Part 15 Class B
Compliant

Audio Outputs

Output Type:

Single-ended with
automatic muting upon
loss CobraNet of signal

Output Impedance:

680 Ω

Maximum Output Level:

+9 dBu

Audio Performance

Noise:

-82 dBu

System THD+N:

< 0.007% - 1 kHz input @ 3
dB below clipping

Frequency Response

20 Hz - 20 kHz, +/- 1 dB

Sample Rate

48 kHz only