Fusion Scan 250 EX™

DMX Traits

Channel

Value

Function

6 LASER
0 - 7 LASER OFF
8 - 15 LASER ON
16 - 131 LASER INTENSITY (VERY SUBTLE)
132 - 247 SOUND ACTIVE
248 - 255 LASER ON

Fusion Scan 250 EX™

Lamp Replacement

Caution:

Always replace with the exact same type lamp and fuse,

unless otherwise specified by an authorized American DJ

®

service

technician. Replacing with anything other than the specified part can
damage your unit and will void your manufactures warranty.

Warning:

If you continue to blow lamps or fuses, STOP using the

unit. Contact customer support for further instructions, you may have
to return the unit for servicing. Continuing to use the unit may cause
serious damage.

Caution! Never open the unit when in use. Always disconnect the
main power before attempting to replace the lamp.
1. Be sure to follow the proper procedures when handling halogen
bulbs.
2. Lamp replacement has been made simple by incorporating the
use of two phillips screws.
3. Loosen and remove the phillips screws on the front bottom cover.
4. Remove the lamp cover and replace the bulb.
5. Reassemble.
Remember to always replace with the exact same type lamp and
fuse, unless otherwise specified by an authorized American DJ
service technician.

This fixture is fitted with a halogen lamp which is
highly susceptible to damage if improperly han-
dled. Never touch the lamp with your bare fingers
as the oil from your hands will shorten lamp life.
Also, never move the fixture until the lamps have
had ample time to cool. Remember, lamps are
not covered under warranty conditions.

American DJ

®

- www.americandj.com - Fusion Scan 250 EX™ Instruction Manual Page 16

Fusion Scan 250 EX™

Fuse Replacement

Locate and remove the unit’s power cord. Once the cord has been
removed located the fuse holder located inside the power socket.
Insert a flat-head screw driver into the power socket and gently pry
out the fuse holder. Remove the bad fuse and replace with a new one.
The fuse holder has a built-in socket for a spare fuse be sure not to
confuse the spare fuse with active fuse.

Fusion Scan 250 EX™

Protective Mirror Cover

A metal cover is provided to protect the scanner mirror during
transportation and storage. The protective cover is held in place
by two thumb screws.

Thumb Screws