10 the vp-460 rs-232 communication protocol, 1 the protocol 3000 common operation commands, The vp-460 rs-232 communication protocol – Kramer Electronics VP-460 User Manual

Page 49: The protocol 3000 common operation commands

Advertising
background image

44

VP-460 - The VP-460 RS-232 Communication Protocol

10 The VP-460 RS-232 Communication Protocol

The Kramer Protocol lets you control the

VP-460 from any standard terminal

software (for example, the Windows

®

HyperTerminal Application).

This section describes the:

Protocol 3000 common commands, see

Audio video control commands (via protocol 3000), see

Section 10.1

The button functions (on the front panel and remote controller), see

Section 10.2

The protocol 3000 communications protocol uses a data rate of 115200 baud, with
no parity, 8 data bits, and 1 stop bit.

Section

10.3

10.1 The Protocol 3000 Common Operation Commands

Operation commands

Command

Syntax

Response

Lock front panel

LOCK-FP LOCK-MODE

LOCK-FP LOCK-MODE

RESULT

Get front panel

locking state

LOCK-FP?

LOCK-FP LOCK-MODE

Parameters Description:

LOCK-MODE

= Front panel locking state:

"0" or "off" to unlock front panel buttons.

"1" or "on" to lock front panel buttons.
Power state

POWER POWER-MODE

POWER POWER-MODE

RESULT

Get power state

POWER?

POWER POWER-MODE

Parameters Description:

POWER-MODE

= power state:

"0" or "off" to enter standby mode.

"1" or "on" to power up.

Restart device

RESET

RESET OK

Peripheral firmware

update execute*

UPGRADE

UPGRADE OK

Usually the firmware will upload to the device via a command such as LDFW

A device reset may be needed to complete the process
Video core Firmware UPGRADES

UPGRADES OK

Advertising