VP-731 - VP-731 Communication Protocol

61

61

Control Type

Function Parameter

Description

Set

Get

<= (HT-92)

0

1

123

0: Negative polarity

1: Positive polarity

Advance Output Mode: HP

0

1

124

384~2047

Advance Output Mode: VT

0

1

125

2~(HS-13)

Advance Output Mode: VW

0

1

126

15~(VT-VA-1)

Advance Output Mode: VS

0

1

127

480~1200

<= (VT-16)

Advance Output Mode: VA

0

1

128

0: Negative polarity

1: Positive polarity

Advance Output Mode: VP

0

1

129

25 < OCLK < 165

Advance Output Mode: OCLK(Integer)

0

1

130

25 < OCLK < 165

Advance Output Mode: OCLK(Decimal)

0

-

131

N/A

Advance Output Mode: Save

0

-

132

N/A

Advance Output Mode: Set Current

0

-

133

N/A

Volume Up

0

-

134

N/A

Volume Down

0

1

135

0: Follow Output

1: Follow Input

HDCP Setting

0

1

136

0:Custom1

1:Custom2

2:Custom3

3:Custom4

Advance Input Mode: Custom Input

0

1

137

0:Custom1

1:Custom2

2:Custom3

3:Custom4

Advance Output Mode: Custom Output

0

1

138

0: Off

1: On

Overscan

0

1

139

0: Seamless

1: Fast

Switching Mode

0

1

140

0: Manual

1: Auto

Auto Image Mode

0

-

141

N/A

Slideshow Start

0

-

142

N/A

Slideshow Stop

0

-

143

N/A

Slideshow Pause

0

-

144

N/A

Slideshow Next

0

-

145

N/A

Slideshow Previous

0

1

146

0: Min

1: Low

2: Mid

3: Long

4: Max

5: Off

Slideshow

0

1

147

0: 1280x768x60

1: 1366x768x60

Mode Set – Mode 3

0

1

148

-100 ~ 100

Red Saturation

0

1

149

-100 ~ 100

Green Saturation